CE Certified Lightning Protection ProductsExporting to 27 Countries Worldwide19+ Years of Engineering ExcellenceFree Technical Consultancy AvailableESE Active Lightning Rods — NFC 17-102 & IEC 62305 CompliantNew: ORBetter® Earthing Enhancement SolutionCE Certified Lightning Protection ProductsExporting to 27 Countries Worldwide19+ Years of Engineering ExcellenceFree Technical Consultancy AvailableESE Active Lightning Rods — NFC 17-102 & IEC 62305 CompliantNew: ORBetter® Earthing Enhancement Solution
Free of Charge — No Commitment Required

LIGHTNING PROTECTION
CONSULTANCY &
ENGINEERING DESIGN

19 years of field experience across 27 countries. Whatever your project — a factory, an airport, a solar farm or a single building — our engineers will design the complete protection system and deliver full documentation, at no cost to you.

What's Included — Free
NFC 17-102 / IEC 62305 risk assessment calculation
Protection level determination (Level I–IV)
ESE lightning rod selection and positioning
Earthing system design and resistance target
SPD coordination for internal protection
Technical drawings and documentation
Product recommendation and bill of materials
19+
Years engineering experience
27+
Countries served
10+
Industry sectors
CE
Certified products & systems
What We Do
Engineering Services

Our consultancy covers the full scope of lightning protection engineering — from initial risk assessment to post-installation audit. Every service is delivered by experienced engineers to international standards.

Lightning risk assessment
Risk Assessment & Protection Level Design
Full NFC 17-102 and IEC 62305-2 risk assessment for your structure. We calculate Nd (expected strike frequency), Nc (tolerable limit), determine the required protection efficiency and assign the correct protection level. Output includes a signed calculation report.
NFC 17-102IEC 62305-2Free
Lightning protection system design
Complete LPS System Design
End-to-end lightning protection system design covering the external LPS (air termination, down conductors, earthing) and internal LPS (equipotential bonding, SPD coordination). We deliver technical drawings, component specifications and a full bill of materials.
External LPSInternal LPSFree
Earthing system design
Earthing & Grounding System Design
Soil resistance measurement analysis, electrode configuration design and resistance target verification. We specify the correct ORBITAL earthing products — solid copper rods, copper-bonded rods or ORBetter® compound — to achieve ≤10Ω in any soil condition.
IEC 62305-3EN 50164Free
SPD surge protection design
Surge Protection (SPD) Design
Coordinated Type 1/2/3 SPD selection for power distribution systems, data lines and telecommunications. We map your LPZ boundaries, specify the correct OSPD series devices and verify voltage protection level (Up) coordination across all stages.
IEC 61643LPZ DesignFree
Lightning forensic audit
Site Audits & Forensic Studies
On-site or remote audit of existing lightning protection systems — gap analysis, compliance verification, damage investigation and forensic lightning strike analysis. We identify system deficiencies and provide a prioritised remediation plan.
Gap AnalysisComplianceExpert Testimony
Renewable energy lightning protection
Specialised Industry Design
Dedicated engineering consultancy for high-complexity sectors: oil & gas, aviation, mining, defence, power utilities and renewable energy. These environments require site-specific analysis beyond standard design procedures — ORBITAL has the field experience.
Oil & GasAviationRenewablesMining
Why Free?
We Provide Final Solutions
With Our Products.

We offer free engineering consultancy because we believe a properly designed system — not just a product sale — is what creates long-term protection and a long-term relationship.

When you bring us your project, we design the right system for your specific conditions: soil type, lightning density, structure dimensions, occupancy, and risk profile. We specify only what you actually need. There is no upselling, no unnecessary complexity.

The result is a compliant, cost-effective installation that you can document, certify and stand behind — and a supplier relationship built on engineering credibility, not just price.

Send Us Your Project →
01
Manufacturer-Direct Engineering
We design with the same products we manufacture. No intermediaries, no generic specifications. Every recommendation is backed by our own test data and field installation experience.
02
International Standards Compliance
Every design is produced to NFC 17-102, IEC 62305 and EN 50164. We provide the documentation required for project approval, insurance compliance and regulatory sign-off in your country.
03
Global Field Experience
Our products are installed across 27 countries in environments ranging from desert to tropical rainforest. We understand how local conditions — soil resistivity, lightning density, corrosive atmosphere — affect system design.
04
Fast Turnaround
Send us your project details — drawings, dimensions, location, facility type. We return a complete design package within a working week for standard projects.
Industry Experience
Sectors We Serve
How It Works
From Enquiry to Design — 4 Steps
01
Send Your Project Details
Share your facility type, location, building dimensions and any existing drawings via email or WhatsApp. A photo of the site is enough to get started.
02
Risk Assessment
Our engineers conduct the NFC 17-102 risk assessment, determine the required protection level and identify all system components needed for a compliant installation.
03
System Design & Documentation
We prepare the complete system design — lightning rod positioning, earthing layout, SPD specification — with technical drawings and a full product bill of materials.
04
Product Supply & Support
We supply the specified ORBITAL products direct from our facility, with full test certificates and ongoing technical support through installation and commissioning.
Ready to Start?
Tell Us About
Your Project.

No forms, no delays. Send us your project details directly by email or WhatsApp and an ORBITAL engineer will respond within one business day — with a complete assessment, not a sales pitch.

ORBITAL Lightning Protection — Risk Calculator
A. Project / Facility Info
1. Building Dimensions (metres)
2. Risk Coefficients
3. ESE Lightning Rod Parameters

Enter your building dimensions and risk
coefficients on the left, then click
Calculate to see the full NFC 17-102 analysis.