Products Info:
ZERU ESE LIGHTNING TERMINAL
ZERU Early Streamer Emission (ESE) lightning terminal can anticipate all other elements and items within its protectable range according to its protection level radius by intercepting the lightning strikes and conducting these strikes into the earth ground through the safest and projected ways. ZERU ESE Terminal work as to principle of creating IONs by its internal ION GENERATION channels. This structure itself allows the terminal to conduct the high voltage lightning strikes to the earthing system then to the earth at the safest way.
►High voltage impulse emitter
►Completely autonomous
►High quality stainless steel components
►Electroatmospheric capacitor-inside
►ION GENERATOR unit
►Testable with ORBITAL Testers
►Fully compatible with the standards
SPECIFICATIONS | ATTRIBUTES | ||||||
---|---|---|---|---|---|---|---|
Material | Stainless Steel | ||||||
Weight | 3.60 kg | ||||||
Ext. Diameter (Ø) | 155mm. | ||||||
Lenght (h) | 58cm. | ||||||
Box Lenght | 62cm. | ||||||
Rod Diameter (Ø) | 20mm. | ||||||
Adapter Diameter | 60mm | ||||||
Max. Current | 200kA | ||||||
Adv. Time (DeltaT) | 60 microsec. | ||||||
PROTECTION FORMULA
ZERU ESE PROTECTION RADIUS TABLE
Height(m) |
Protection Radius(m)
|
|||||
---|---|---|---|---|---|---|
Level 1 | Level 2 | Level 3 | Level 4 | |||
2 | 31 | 35 | 39 | 43 | ||
4 | 63 | 69 | 78 | 85 | ||
5 | 79 | 86 | 97 | 107 | ||
10 | 79 | 88 | 99 | 109 | ||
ZERU DeltaT Advance Time Test Certificate(NFC 17/102-2011 Edition)
With 19 years long experience in both field and research&development ORBITAL's all products are fully compatible with regarded and respected standards. ZERU ESE system fulfils the full requirements contained in the norms of NFC 17/102-2011.
For confidential reasons only a part of the certificate is provided. Please contact ORBITAL for full document.
ZERU 200kA Current Withstanding Test Certificate(NFC 17/102-2011 Edition)
In NFC 17/102-2011 Standard, minimum current withstanding threshold is stated as 100kA. ORBITAL ESE Terminals is tested and passed 200kA current successfully. Even though only 1% of lightning strikes is surpassing 200kA voltages, you are fully protected by ORBITAL Lightning Protection system.
For confidential reasons only a part of the certificate is provided. Please contact ORBITAL for full document.
ZERU European Conformity Certificate
ORBITAL Lightning Protection products are manufactured completely in accordance with European Union Conformity Standards. From the smallest parts to packaging every components are under control and under the inspection of both internal and external controls.
For confidential reasons only a part of the certificate is provided. Please contact ORBITAL for full document.
INSTALLATION STRUCTURE
TECHNICAL CHARACTERISTICS
Material | 304L Stainless Steel | |||
Weight | 3.6 kg. | |||
IP Code | IP65 | |||
Working Temperature | -25C / 90C | |||
Type of Terminal | Electroatmospheric | |||
Internal Insulation | High Density Polyurethane Resin | |||
Adapter | 60mm Male Mast | |||
Standard | NFC 17-102/2011 | |||
Grounding Method | Wire/Tape | |||